schema monofilara conceptuala a dsicc_fuse_se_v-400.pdf
LegendaÀ1.1-A2.1- terminal numeric de monitorizare DSICCÀ1.2-A2.2- terminal control starea izolatiei pe conexiuniDT- traductori de masurare curent sau tensiuneÀ3.1, À3.2- sistem protectie tensiunea inversa (puntea de diode)À- ampermetru;V- voltmetru;KV- releu de tensiune;KS- releu semnalizare defect de punere la pamant;***- sunt indicate lungimile, sectiunile si materialul cablurilor existente pe tronsoane, care trebuie inlocuite. Dulap Racord 1 (Racord BA Nr.1, Reresor 1, Redresor 3) Q2 Q1ÐÅ1QFU3 1QFU161QFU171QFU181QFU191QFU201QFU211QFU221QFU23 +EY1-EY1 +EÑ1-EÑ1 +EY2-EY2 +EÑ2-EÑ2 Dulap(uri) Distributie Sectia 1~= A À1.1 (TN monitorizare DSICC) A1QFU41QFU7 1QFU241QFU251QFU261QFU271QFU281QFU29 1QFU51QFU61QFU8 -104 element+1 element260 À*h1FU31FU21FU11FU31FU21FU1BSE1 Blocul de Siguranțe Externe 1QS1ADTVCu, 2x70L=20 m 1Q11Q51QS4 ~= 1QS3 2FU32FU22FU12FU32FU22FU1 2QS1A Cu, PV3 1x70L=5m 2QS32QS4 ~= 2Q22Q5QS11Q3 QS21Q6 +ED-ED 2Q6 1QFU91QFU101QFU111QFU121QFU131QFU141QFU15A 1QFU30 2QFU3À3.22QFU12QFU42QFU72QFU52QFU62QFU82QFU92QFU102QFU112QFU122QFU132QFU142QFU15 2QFU162QFU172QFU182QFU192QFU202QFU212QFU222QFU232QFU242QFU252QFU262QFU27--2QFU282QFU29-2QFU30 DTDT DT DT DT DT DT DTÀ2.1 (control izolatie pe conexiuni) Dulap(uri) Distributie Sectia 2Dulap Racord 2 (Racord BA Nr.2, Reresor 2) Modernizare DSICC la SE Vulcănești Conceptul DSICC pe baza utilizării siguranțelor fuzibile. Концепт ЩПТ на базе применения предохранителей DSICA Sectia nr. 1Bateria de acumulatoare nr, 1DSICA Sectia nr. 2Bateria de acumulatoare nr. 2DSICA Sectia nr. 2-104 element+1 element250 À*hRedresor 1Redresor 3Redresor 2Cu, 3x16*L=10 m Cu, PV3 1x70L=5mCu, 3x16*L=10 m Cu, 3x16*L=10 mBSE1 Blocul de Sigurante Externe Cu, 2x70L=20 mCu, PV3 1x70L=5mCu, PV3 1x70L=5m A A ADT VDTV V Curent, ÀPuterea, kVASistem protectia tensiunea inversaTip, marcasectiunelungimea cabluluiDestinatia conexiunilorInel DC IDD-110 kV (DCO)Inel DC IDD-400 kV MGRES+2AT+TV2C (DCO)Inel DC IDD-400 kV reactor 1 (DCO)Alimentare statia de pompare la IDDAtelier PRABloc alimentare iluminre de siguranta (ÁÀÎ - áëîê àâàðèéíîãî îñâåùåíèÿ)RezervaIntreruptoare 35 kV (Rezerva pe viitor)100ÀInel DC IDD-35 kV (DCO)Inel DC IDD-400 kV Isaccea+separatoare reactor (DCO)Inel DC IDD-400 kV Chisinau+1AT+TV1C (DCO)Inel DC IDD-400 kV reactor 2 [reactor] (DCO) RezervaRezerva 1QFU2À3.11QFU1 100À V V Curent, ÀPuterea, kVASistem protectia tensiunea inversaTip, marcasectiunelungimea cabluluiDestinatia conexiunilorInel DC IDD-110 kV (DCO)Inel DC IDD-400 kV MGRES+2AT+TV2C (DCO)Inel DC IDD-400 kV reactor 1 (DCO)Alimentare statia de pompare la IDDAtelier PRABloc alimentare iluminre de siguranta (ÁÀÎ - áëîê àâàðèéíîãî îñâåùåíèÿ)RezervaIntreruptoare 35 kV (Rezerva pe viitor)100ÀInel DC IDD-35 kV (DCO)Inel DC IDD-400 kV Isaccea+separatoare reactor (DCO)Inel DC IDD-400 kV Chisinau+1AT+TV1C (DCO)Inel DC IDD-400 kV reactor 2 [reactor] (DCO) RezervaRezerva100À VDT VDT VDT 2QFU2 Curent, ÀPuterea, kVACCC. DDCO 1AT, 2AT, PDB-400, TV1C, T
toare reactor (DCO)Inel DC IDD-400 kV Chisinau+1AT+TV1C (DCO)Inel DC IDD-400 kV reactor 2 [reactor] (DCO) RezervaRezerva100À VDT VDT VDT 2QFU2 Curent, ÀPuterea, kVACCC. DDCO 1AT, 2AT, PDB-400, TV1C, TV2CTip, marcasectiunelungimea cabluluiDestinatia conexiunilorCCC. DDCO LEA 400 kVCCC. Semnalizarea centrala (p.5)CCC. Reteaua locala (p.83)Centru de comunicatii (invertor 1)Grupul de destinatie generala (DSIAC, SASI)Grupul de alimentare dispozitive de masurare, evidentaRezerva CCC. DDCO reactorCCC. DDCO LEA 110 kV (p.75)CCC. DDCO LEA 110 kV (p.76)CCC. Dulap DC/DC convertor (p.20) RezervaRezervaRezerva Curent, ÀPuterea, kVACCC. DDCO 1AT, 2AT, PDB-400, TV1C, TV2CTip, marcasectiunelungimea cabluluiDestinatia conexiunilorCCC. DDCO LEA 400 kVCCC. Semnalizarea centrala (p.5)CCC. Reteaua locala (p.83)Centru de comunicatii (invertor 2)Grupul de destinatie generala (DSIAC, SASI)Grupul de alimentare dispozitive de masurare, evidentaRezerva CCC. DDCO reactorCCC. DDCO LEA 110 kV (p.75)CCC. DDCO LEA 110 kV (p.76)CCC. Dulap DC/DC convertor (p.20) RezervaRezervaRezerva DT DT DT DT VDT VDT de la sectia 2 (2SF8)1SA1de la sectia 1 (1SF8) A 2SA12SF72SF81SF11SF21SF81SF7la sectia 1 (SA1)la sectia 1 (SA2)2SF12SF2 1SF51SF6 2SF52SF6 1SF31SF41SF91SF10À1.2 (TN monitorizare DSICC)À2.2 (control izolatie pe conexiuni)2SF92SF102SF32SF4KV1UmaxKV2UminKV3UmaxKV4Umin KV5UmaxKV6Umin KV1UmaxKV2UminKV3UmaxKV4Umin KV5UmaxKV6UminKS3Ñontrolul izolatiei KS2Ñontrolul izolatieiKS1Ñontrolul izolatieiKS1Ñontrolul izolatieiKS2Ñontrolul izolatiei KS3Ñontrolul izolatiei
Previzualizarea are caracter informativ. Doar originalul oficial din sursă are valoare juridică.